The company has received the ISO 9001:2000 certificate
from M/s. DNV.
The following are the features and advantages
of JVS products.
1) PROTECTIVE RELAYS
i) Standard 144 mm.sq. DIN size draw-out
case having fixed depth of 232 mm: This means that any
relay, irrespective of the number of poles / elements required,
will be supplied in a standard case. This will reduce the cost of
fabrication as well as the time of fabrication, in so far as switchgear
and panel manufactures are concerned. The fabrication drawings can
be prepared well in advance without waiting for final order acceptance
from us, as all the relays will be in the same size of case.
ii) Software based, programmable relays:
This will again reduce the time of procurement and also inventory.
As relays are programmed, it is not necessary to specify the characteristics
in advance. A standard relay can be ordered and used for the desired
application (e.g. Our software based, programmable, inverse time
relay has all the four characteristics viz. standard inverse 3 secs.
and 1.3 secs., very inverse and extremely inverse, any one of which
can be selected as required.
iii) Wide setting range: The wide
settings ranges available in current operated relays are
a) O/C setting - 50 to 200% in steps of 10%
b) E/F setting - 5 to 80% in steps of 5%
c) O/C highset - 200 to 3000% in steps of 200%
d) E/F highset - 50 to 800% in steps of 50%
These wide setting ranges cover almost all the
requirement of users. The variable parameters are limited and so
ordering of relays in advance becomes easy and thereby reduces the
overall delivery times of both panels and switchgear. Customers
can even go in for short-term stocks.
iv) Very low burdens: The burdens
of the CTs on account of these relays is very low as compared to
electromechanical relays. The burden is constant throughout the
operating range. Further, There are indirect benefits in the form
of CT & PT costs. The size of CTs can be reduced considerably.
For example, for inverse time relays, it is no longer necessary
to use 15 VA ALF10 or 30 VA ALF15 CTs. It is sufficient to use 5
VA ALF5 CTs and these will be adequate even if the earth fault element
is set at 5%. Such facilities are not available on electromechanical
relays.
v) Shorter Deliveries: In view
of the fact that most of the relays are highly standardised and
production / testing facilities are also automated, the overall
delivery times get reduced considerably. The maximum delivery period
for some of the more complicated relays will not be more than 10
/ 12 weeks while for most of the other relays, it is of the order
of 4 / 6 weeks.
vi) Maintenance free: The design
as well as the use of hirel components makes the relays totally
maintenance free. The mother board technology used in the relays
enables replacement of a faulty PCB without much delay. Customers
have to keep only the PCBs as spares and not entire relays. This
will also result in reduction of spares inventory.
2) EARTH LEAKAGE AND EARTH FAULT RELAYS
These relays are available in either flush mounting
or DIN rail mounting case. The relays are provided with bar graph
indication to indicate the leakage in the system.
3) 'J-WATCH' FACIA ANNUNCIATORS
The annunciator is provided with built-in push
buttons and site selection of trip, non-trip function and also the
selection of standard ISA seqeunce of operation. Provided with RS232
communication port(optional).
4) MICROPROCESSOR BASED PANEL
METERS AND TIMERS, COUNTERS, TIME INTERVAL METERS AND HOUR METER
These are of flush mounting type having wide range,
very high accuracy and flexiblity in selecting various operationg
modes at site.
5) ELECTROMECHANICAL, AUXILIARY AND HIGH
SPEED TRIPPING RELAYS
The electromechanical auxiliary and high speed
tripping relays are of attracted armature type. These relays are
supplied in plug-in type cases which offer considerable advantages
and flexibility to the users. These relays can be offered either
with self reset or hand reset and electrical reset contacts. We
have developed a special case, wherein number of elements from 1
to 6 can be supplied in a single case so that total requirement
of a particular application can be met with a single case without
going in for multiple cases for auxiliary and tripping relays |